ICRP Publication 156

Paediatric Mesh-type Reference Computational Phantoms

Recommended citation
ICRP, 2024. Paediatric mesh-type reference computational phantoms. ICRP Publication 156. Ann. ICRP 53(1-2)

Authors on behalf of ICRP
C.H. Kim, C. Choi, W.E. Bolch, N. Petoussi-Henss, M. Zankl, C. Lee, B. Shin, Y.S. Yeom, T.T. Nguyen, H. Han, B.S. Chung, K. Eckerman, R. Qiu, S. Kim, G. Son

Abstract - Following the issuance of the 2007 Recommendations in Publication 103, the Commission released the adult (male and female) and paediatric (newborn, 1-, 5-, 10-, and 15-year-old male and female) reference computational phantoms in Publications 110 and 143, respectively, for use in effective dose calculations. These phantoms are voxel models represented in the form of a three-dimensional array of cuboidal voxels, which were constructed from computed tomography images of people and adjusted to be consistent with the reference anatomical parameters given in Publication 89. The voxel phantoms provide anatomical improvements over the mathematical-equation-based stylised phantoms used for the previous dose coefficient (DC) calculations prior to the 2007 Recommendations. Nevertheless, the voxel phantoms, due to the nature of voxel geometry and finite voxel resolutions, have limitations in representing small and thin organs and tissues, necessitating additional supplementary stylised models such as those defined for the respiratory tract airways, the alimentary tract organ walls and stem cell layers, the lens of the eye, and the skin basal layer. To address the limitations of the voxel phantoms, Task Group 103 was charged with developing mesh-type reference computational phantoms (MRCPs) by converting the voxel phantoms into a high-quality/fidelity mesh format with anatomical improvements for the complex organs and tissues which were not represented fully in the voxel phantoms. MRCPs for the adult male and female were then developed and released recently in Publication 145. Following the release of the adult MRCPs, the current publication describes the construction of the paediatric MRCPs, the counterparts of the Publication 143 voxel phantoms. The paediatric MRCPs, like the adult MRCPs, were developed to have all the source and target tissues required for calculation of effective dose, including the micrometre-scale regions, assimilating the supplementary stylised models. These phantoms can be used directly in general purpose Monte Carlo codes, such as Geant4, PHITS, and MCNP6, fully maintaining the high fidelity of the mesh geometry in Monte Carlo dose calculations. To investigate the impact of the paediatric MRCPs, the DCs of organ dose and effective dose and specific absorbed fractions (SAFs) for some selected external and internal exposures were calculated and compared with the values calculated using the Publication 143 phantoms, the Publication 66 and 100 mathematical models for the respiratory and alimentary tracts, and the reference values of Publication 155. While some differences in the DCs and SAFs were observed for anatomically improved organs and weakly penetrating radiations, they were found to be fairly similar, indicating that the reference DCs obtained from the Publication 143 voxel phantoms for both external and internal exposures remain valid in the current ICRP dosimetry system. The Publication 143 voxel phantoms remain the primary ICRP/International Commission on Radiation Units and Measurements reference models for the calculation of reference DCs based on Publication 103 methodology. The paediatric MRCPs will be used for all calculations of reference DCs following the next set of ICRP general recommendations, and provide a resource for wider use in radiological protection applications.

MAIN POINTS

· This publication presents paediatric mesh-type reference computational phantoms (MRCPs) representing the reference male and female at 0 (i.e. newborn), 1, 5, 10, and 15 years of age, which are counterparts of the paediatric voxel-type reference computational phantoms in Publication 143 (ICRP, 2020a) developed based on computed tomography images of real people.

· The paediatric MRCPs were constructed by converting the Publication 143 voxel phantoms (ICRP, 2020a) to a high-quality mesh format, assimilating the supplementary stylised models used in conjunction with the voxel phantoms to overcome limitations of voxel geometry, and adding tissue layers that are considered to contain cells at risk of radiogenic cancer.

· The paediatric MRCPs include all the necessary source and target tissues defined by the ICRP system for effective dose calculations, including the micrometre-thick source and target layers of the alimentary and respiratory tracts, skin, and urinary bladder, as well as dose calculations for the lens of the eye.

· The paediatric MRCPs were found to provide dose coefficients (DCs) and specific absorbed fractions that are similar to those of the Publication 143 voxel phantoms (ICRP, 2020a) for both external and internal exposures, while some differences were observed for anatomically improved organs and weakly penetrating radiations (e.g. photons <50 keV and electrons).

· The Publication 143 voxel phantoms (ICRP, 2020a) remain the primary ICRP/International Commission on Radiation Units and Measurements reference models for the calculation of reference DCs based on Publication 103 methodology (ICRP, 2007), but the paediatric MRCPs will be used for all calculations of reference DCs following the next set of ICRP general recommendations, and also serve as a resource for wider use in radiological protection applications.